DocumentCode
2501231
Title
Study on the ultra-wideband characteristics of some typical interference signals
Author
Cheng, Yonghong ; Xie, Hengkun ; Li, Wei
Author_Institution
State Key Lab. of Electr. Insulation for Power Equip., Xi´´an Jiaotong Univ., China
fYear
1998
fDate
27-30 Sep 1998
Firstpage
689
Lastpage
692
Abstract
As is well known the accuracy and credibility of partial discharge measurement might be influenced seriously by surrounding interference. Using the technique of ultra-wideband partial discharge detection, we have studied the characteristics of some typical period interference and random interferences, including brush discharge interference, operating high-voltage interference, operating computer interference, rectifier interference and so on. The experimental results that the characteristics of these interferences can be distinguished either in time-domain or in frequency-domain, particularly, based on the characteristic frequency peak and the shape of characteristic peak by using digital analysis technique. It is helpful for the development of the insulation diagnosis technique
Keywords
electromagnetic interference; insulation testing; partial discharge measurement; brush discharge interference; computer interference; digital analysis; fingerprint; frequency-domain analysis; high-voltage interference; insulation diagnosis; interference signal; partial discharge measurement; rectifier interference; time-domain analysis; ultra-wideband characteristics; Brushes; Frequency domain analysis; Insulation; Interference; Partial discharge measurement; Partial discharges; Rectifiers; Shape; Time domain analysis; Ultra wideband technology;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulating Materials, 1998. Proceedings of 1998 International Symposium on
Conference_Location
Toyohashi
Print_ISBN
4-88686-050-8
Type
conf
DOI
10.1109/ISEIM.1998.741837
Filename
741837
Link To Document