DocumentCode
2501247
Title
Study on characteristics of ultra-wideband partial discharge of typical insulation samples
Author
Cheng, Yonghong ; Xie, Hengkun ; Li, Wei
Author_Institution
State Key Lab. of Electr. Insulation for Power Equip., Xi´´an Jiaotong Univ., China
fYear
1998
fDate
27-30 Sep 1998
Firstpage
697
Lastpage
700
Abstract
In recent years, high frequency technique is applied for partial discharge detection extensively. Using the ultra-wideband partial discharge detecting system developed by authors, the characteristic of time-domain and frequency-domain of some typical insulation samples are studied. The ultra-wideband partial discharge characteristics of original epoxy sample involving cavities with cone-cone, needle-plate electrode system and epoxy sample involving metal interface with needle-plate electrode system are presented in this paper. And ultra-wideband partial discharge characteristics in aging process of insulation samples are also presented. From the experimental results, it is obvious that different types of partial discharge have their particular frequency characteristic and waveform, and can be distinguished in frequency-domain. It is important for insulation diagnosis
Keywords
ageing; epoxy insulation; insulation testing; partial discharge measurement; aging; cavity; cone-cone electrode system; epoxy insulation diagnosis; frequency domain analysis; high frequency technique; metal interface; needle-plate electrode system; time domain analysis; ultra-wideband partial discharge detection; Cutoff frequency; Electrodes; Frequency measurement; Insulation; Oscilloscopes; Partial discharge measurement; Partial discharges; Sensor phenomena and characterization; Sensor systems; Ultra wideband technology;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulating Materials, 1998. Proceedings of 1998 International Symposium on
Conference_Location
Toyohashi
Print_ISBN
4-88686-050-8
Type
conf
DOI
10.1109/ISEIM.1998.741839
Filename
741839
Link To Document