• DocumentCode
    2501618
  • Title

    Methods for speeding up radiated and conducted immunity tests

  • Author

    Pommerenke, David

  • Author_Institution
    Hewlett Packard, Roseville, CA, USA
  • Volume
    2
  • fYear
    2000
  • fDate
    2000
  • Firstpage
    587
  • Abstract
    Different methods for reducing test time in immunity tests similar to IEC 61000-4-6 or IEC 61000-4-3 are compared. One option is to apply multiple signals at the same time. Hardware and software methods to create those signals are explained, limits and possible amplitude errors are discussed. Mode stirred chambers and methods which aim at substituting sinusoidal excitation by strong pulsed signals are not within the scope of this paper
  • Keywords
    IEC standards; electromagnetic interference; measurement errors; measurement standards; EMI; IEC 61000 standards; IEC 61000-4-3; IEC 61000-4-6; amplitude errors; conducted immunity tests; hardware methods; multiple signals; radiated immunity tests; sinusoidal excitation; software methods; test time reduction; Cables; Delay; Hardware; IEC standards; Maintenance engineering; Polarization; RF signals; Radio frequency; Signal generators; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 2000. IEEE International Symposium on
  • Conference_Location
    Washington, DC
  • Print_ISBN
    0-7803-5677-2
  • Type

    conf

  • DOI
    10.1109/ISEMC.2000.874686
  • Filename
    874686