DocumentCode
2501723
Title
A calibration procedure for reverberation chambers
Author
Hatfield, Michael O.
Author_Institution
Naval Surface Warfare Center, Dahlgren, VA, USA
Volume
2
fYear
2000
fDate
2000
Firstpage
621
Abstract
This paper documents a calibration procedure for reverberation chambers. The method described was developed as part of an ongoing effort to introduce reverberation chambers into military and commercial standards. This work was conducted in cooperation with both industry and standards organizations. The effort described herein is intended to provide an accurate and economic methodology for calibrating reverberation chambers. The methodology was initially developed and evaluated at the Naval Surface Warfare Center, Dahlgren Division. Follow-on evaluations were conducted at facilities owned and operated commercially
Keywords
calibration; electromagnetic shielding; measurement standards; military standards; reverberation chambers; Naval Surface Warfare Center; accurate method; calibration procedure; commercial standards; economic method; industry; military standards; reverberation chambers; shielding effectiveness; standards organizations; susceptibility testing; Boundary conditions; Calibration; Electronic equipment; Electronic equipment testing; Immunity testing; Military standards; Receiving antennas; Reverberation chamber; Standards development; Tuners;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility, 2000. IEEE International Symposium on
Conference_Location
Washington, DC
Print_ISBN
0-7803-5677-2
Type
conf
DOI
10.1109/ISEMC.2000.874692
Filename
874692
Link To Document