• DocumentCode
    2501723
  • Title

    A calibration procedure for reverberation chambers

  • Author

    Hatfield, Michael O.

  • Author_Institution
    Naval Surface Warfare Center, Dahlgren, VA, USA
  • Volume
    2
  • fYear
    2000
  • fDate
    2000
  • Firstpage
    621
  • Abstract
    This paper documents a calibration procedure for reverberation chambers. The method described was developed as part of an ongoing effort to introduce reverberation chambers into military and commercial standards. This work was conducted in cooperation with both industry and standards organizations. The effort described herein is intended to provide an accurate and economic methodology for calibrating reverberation chambers. The methodology was initially developed and evaluated at the Naval Surface Warfare Center, Dahlgren Division. Follow-on evaluations were conducted at facilities owned and operated commercially
  • Keywords
    calibration; electromagnetic shielding; measurement standards; military standards; reverberation chambers; Naval Surface Warfare Center; accurate method; calibration procedure; commercial standards; economic method; industry; military standards; reverberation chambers; shielding effectiveness; standards organizations; susceptibility testing; Boundary conditions; Calibration; Electronic equipment; Electronic equipment testing; Immunity testing; Military standards; Receiving antennas; Reverberation chamber; Standards development; Tuners;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 2000. IEEE International Symposium on
  • Conference_Location
    Washington, DC
  • Print_ISBN
    0-7803-5677-2
  • Type

    conf

  • DOI
    10.1109/ISEMC.2000.874692
  • Filename
    874692