• DocumentCode
    2504352
  • Title

    PLL with PI, PID and Fuzzy Logic Controllers based shunt Active Power Line Conditioners

  • Author

    Karuppanan, P. ; Mahapatra, KamalaKanta

  • Author_Institution
    Dept. of Electron. & Commun., Nat. Inst. of Technol., Rourkela, India
  • fYear
    2010
  • fDate
    20-23 Dec. 2010
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    This paper presents a novel Phase Locked Loop (PLL) circuit in conjunction with Proportional Integral (PI) or Proportional Integral Derivative (PID) or Fuzzy Logic Controller (FLC) based shunt Active Power Line Conditioners (APLC) for the power-quality improvement such as current harmonics and reactive power compensation due to the non-linear/unbalanced loads. The shunt APLC system is implemented with three phase current controlled Voltage Source Inverter (VSI) and is connected at the point of common coupling for compensating the current harmonics by injecting equal but opposite filter currents. The compensation process is based on PLL synchronization with PI or PID or fuzzy logic controller. These controllers are capable of controlling dc-side capacitor voltage and estimating reference currents. Hysteresis Current Controller (HCC) is used to generate switching signals for the voltage source inverter. Extensive simulation studies under different non-linear and unbalanced load conditions are conducted, this simulation results analysis reveals that the APLC system performs perfectly with PI, PID and fuzzy logic control strategy. A comparative assessment of the three different controllers has been disclosed.
  • Keywords
    PI control; fuzzy control; hysteresis; phase locked loops; power cables; three-term control; PI controller; PID controller; PLL synchronization; fuzzy logic controller; hysteresis current controller; phase locked loop circuit; proportional integral controller; proportional integral derivative controller; reactive power compensation; shunt active power line conditioner; voltage source inverter; Active filters; Fuzzy logic; Harmonic analysis; Phase locked loops; Power harmonic filters; Voltage control; Fuzzy logic controller (FLC); PI; PID; PLL synchronization; active power line conditioners (APLC); hysteresis current controller (HCC);
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics, Drives and Energy Systems (PEDES) & 2010 Power India, 2010 Joint International Conference on
  • Conference_Location
    New Delhi
  • Print_ISBN
    978-1-4244-7782-1
  • Type

    conf

  • DOI
    10.1109/PEDES.2010.5712506
  • Filename
    5712506