• DocumentCode
    2507675
  • Title

    Performance optimization of direct on line static switch fed three phase induction motor drive

  • Author

    Nafeesa, K. ; George, Saly

  • Author_Institution
    Dept. of Electr. Eng., Nat. Inst. of Technol. Calicut, Kozhikode, India
  • fYear
    2010
  • fDate
    17-19 Dec. 2010
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    This paper describes a thyristorized static switch designed for the operation of Direct On Line starter fed three phase induction motor drive. It establishes the fact that optimum value of firing angle combination for the voltage controller of induction motor depends on the motor parameters. Motors having different parameter values with identical rating are considered for the work. Optimum firing angle combination of the voltage controller is obtained from the extensive simulation results, which gives zero negative torque pulsations with minimum acceleration time. Other factors which are considered for the work are peak starting current, peak positive electrodynamic torque pulsations, nature of voltage and current waveforms and current ripple. Results show that optimum firing angle combination of the voltage controller depends largely on machine parameters.
  • Keywords
    induction motors; machine control; performance evaluation; voltage control; direct on line static switch fed three phase induction motor drive; induction motor; peak positive electrodynamic torque pulsations; performance optimization; thyristorizd static switch; zero negative torque pulsations; Acceleration; Induction motors; Rotors; Stators; Switches; Torque; Voltage control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    India Conference (INDICON), 2010 Annual IEEE
  • Conference_Location
    Kolkata
  • Print_ISBN
    978-1-4244-9072-1
  • Type

    conf

  • DOI
    10.1109/INDCON.2010.5712684
  • Filename
    5712684