Abstract :
Neutron stimulated emission computed tomography (NSECT) is being developed as a non-invasive technique to measure element concentration in in-vivo tissue at molecular levels. We have developed a system that performs this task using an incident neutron beam that scatters inelastically with an atomic nucleus causing it to emit a characteristic gamma photon. An energy-sensitive gamma detector is used to detect this energy and identify the target atom. Here we describe an experiment to determine the concentration of natural potassium (39K) in bovine liver without the need for a biopsy. A 5 MeV neutron beam was used to scan a known quantity of bovine liver to obtain a gamma spectrum showing element concentration in the liver. An aqueous KCl solution calibration sample was then scanned to establish a ratio of potassium concentration to gamma counts for the experimental setup. Counts from gamma peaks corresponding to excited states in 39K were summed and compared with counts from the known calibration sample, to give the concentration of 39K in the liver. A high purity germanium (HPGe) clover detector was used to measure the emitted gamma energy. The results were validated through neutron activation analysis (NAA) of the liver sample. The concentration of 39K reported by NSECT was found to be within 13% of the NAA result, clearly demonstrating the ability of NSECT for non-invasive quantification of element concentration in tissue.
Keywords :
chemical analysis; chemical variables measurement; emission tomography; germanium radiation detectors; liver; neutron activation analysis; potassium; 5 MeV; 39K; HPGe clover detector; NAA; NSECT; aqueous potassium chloride solution; bovine liver; characteristic gamma emission; element concentration measurement; energy sensitive gamma detector; gamma spectrum; high purity germanium detector; neutron activation analysis; neutron beam inelastic scattering; neutron stimulated emission computed tomography; noninvasive potassium estimation; Bovine; Calibration; Computed tomography; Electromagnetic scattering; Gamma ray detection; Gamma ray detectors; Liver; Neutrons; Particle beams; Stimulated emission;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2006. IEEE
Conference_Location :
San Diego, CA
ISSN :
1095-7863
Print_ISBN :
1-4244-0560-2
Electronic_ISBN :
1095-7863
Type :
conf
DOI :
10.1109/NSSMIC.2006.354322
Filename :
4179436
Link To Document :
بازگشت