• DocumentCode
    2510132
  • Title

    Partial discharge measurements for testing of low-voltage equipment

  • Author

    Koch, H. ; Pfeiffer, W. ; Reinhard, H.

  • Author_Institution
    Tech. Hochschule Darmstadt, West Germany
  • fYear
    1988
  • fDate
    5-8 Jun 1988
  • Firstpage
    229
  • Lastpage
    232
  • Abstract
    The application of PD (partial discharge) measurements to solid insulation within electronic components and assemblies in the low voltage range (e.g. optocouplers, small transformers, and printed wiring boards with coating) for the verification of insulation integrity, is reported. Such measurements are of special interest if such insulation is used to reduce electrical separation. In order to simulate the aging process during the normal life of equipment, different aging procedures were applied. The results of PD measurements after aging are compared with the data obtained before
  • Keywords
    ageing; insulation testing; partial discharges; aging procedures; aging process; coating; electrical separation; electronic components; insulation integrity; low-voltage equipment; optocouplers; partial discharge; printed wiring boards; small transformers; solid insulation; Aging; Assembly; Electronic components; Low voltage; Partial discharge measurement; Partial discharges; Power transformer insulation; Solids; Testing; Wiring;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation, 1988., Conference Record of the 1988 IEEE International Symposium on
  • Conference_Location
    Cambridge, MA
  • ISSN
    1089-084X
  • Type

    conf

  • DOI
    10.1109/ELINSL.1988.13911
  • Filename
    13911