• DocumentCode
    2510210
  • Title

    Preliminary Studies of a Simultaneous PET/MRI Scanner Based on the RatCAP Small Animal Tomograph

  • Author

    Schlyer, D. ; Vaska, P. ; Tomasi, D. ; Woody, C. ; Solis-Najera, S. ; Southekal, S. ; Rooney, W. ; Pratte, J.-F. ; Junnarkar, S. ; Stoll, S. ; Purschke, M. ; Park, S.-J. ; Master, Z. ; Maramraju, S.H. ; Krishnamoorthy, S. ; Kriplani, A. ; Schiffer, W. ; C

  • Author_Institution
    Brookhaven Nat. Lab., Upton, NY
  • Volume
    4
  • fYear
    2006
  • fDate
    Oct. 29 2006-Nov. 1 2006
  • Firstpage
    2340
  • Lastpage
    2344
  • Abstract
    We are developing a scanner that will allow the simultaneous acquisition of high resolution anatomical data using magnetic resonance imaging (MRI) and quantitative physiological data using positron emission tomography (PET). The approach is based on the technology used for the RatCAP conscious small animal PET tomograph which utilizes block detectors consisting of pixelated arrays of LSO crystals read out with matching arrays of avalanche photodiodes (APDs) and a custom-designed ASIC. A version of the detector is being developed that will be constructed out of all nonmagnetic materials that can be operated inside the MRI field. We have demonstrated that the PET detector works inside the MRI field using 511 keV gamma rays, and have obtained MRI images with various detector components that show minimal distortion in the MRI image. We plan to improve on the image quality in the future using completely nonmagnetic components and by tuning the MRI pulse sequences. The combined result will be a highly compact, low mass PET scanner that can operate inside an MRI magnet without distorting the MRI image, and can be retrofitted into existing MRI instruments.
  • Keywords
    avalanche photodiodes; biomedical MRI; data acquisition; positron emission tomography; 511 keV; LSO crystal pixelated arrays; MRI pulse sequence; PET detector; PET-MRI scanner; RatCAP; avalanche photodiodes; custom-designed ASIC; image quality; low mass PET scanner; magnetic resonance imaging; positron emission tomography; simultaneous data acquisition; small animal tomograph; Animals; Application specific integrated circuits; Avalanche photodiodes; Crystals; Gamma ray detection; Gamma ray detectors; Image resolution; Magnetic resonance imaging; Positron emission tomography; Sensor arrays;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2006. IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1095-7863
  • Print_ISBN
    1-4244-0560-2
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2006.354383
  • Filename
    4179497