    Cardiac C-arm CT: Efficient Motion Correction for 4D-FBP

  • Author

    Prummer, M. ; Wigstrom, L. ; Hornegger, J. ; Boese, J. ; Lauritsch, G. ; Strobel, N. ; Fahrig, R.

  • Author_Institution
    Inst. of Pattern Recognition, Friedrich Alexander Univ. Erlangen-Nuremberg, Erlangen
  • Volume
    4
  • fYear
    2006
  • fDate
    Oct. 29 2006-Nov. 1 2006
  • Firstpage
    2620
  • Lastpage
    2628
  • Abstract
    Cardiac C-arm CT is a promising technique that enables 3D cardiac image acquisition and real-time fluoroscopy on the same system. The goal is to bring 3D imaging to the interventional suite for improved therapy planning, guidance, and monitoring. For the reconstruction of 3D cardiac image data, a complete set of projections from a specific heart phase is required. One approach to reduce motion blurring caused by the beating heart is to acquire multiple sweeps using the C-arm and retrospectively select the projections that are closest to the desired cardiac phase. In order to further improve the temporal resolution, novel image processing algorithms that utilize retrospective motion correction were investigated in this study. The main focus of this work is to extend the well established FDK algorithm to incorporate motion correction during the back-projection step using a subject specific computed motion field. In a simulation study we show that motion blurring can be decreased significantly using the subjects´ individual estimated heart motion based on a time series of retrospectively gated FDK reconstructions. In our experiments using an animal model we investigated the following two scenarios: (I) Can the image quality from a single sweep be improved given a subjects´ individual prior computed motion field? (II) Can improved image quality be achieved using the full temporal resolution of a multi-sweep scan for motion estimation in combination with motion correction? Our results show that increasing temporal resolution using an first order estimated 4D motion vector field of the subjects´ individual heart motion in the FDK-4D algorithm can decrease motion blurring substantially for both investigated scenarios.
  • Keywords
    cardiology; computerised tomography; medical image processing; motion compensation; 3D cardiac image acquisition; 3D cardiac image reconstruction; 4D FBP; 4D motion vector field; FDK algorithm; cardiac C-arm CT; computerized tomography; filtered back projection; image processing algorithms; motion blurring reduction; real time fluoroscopy; retrospective motion correction; therapy guidance; therapy monitoring; therapy planning; Computed tomography; Heart; Image processing; Image quality; Image reconstruction; Image resolution; Medical treatment; Monitoring; Motion estimation; Real time systems; Cardiac C-arm CT; FDK-4D; heart motion estimation; retrospective motion correction;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2006. IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1095-7863
  • Print_ISBN
    1-4244-0560-2
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2006.354444
  • Filename
    4179558