• DocumentCode
    2513055
  • Title

    Power analysis of a heat pump with horizontal collectors

  • Author

    Craciun, Adrian Virgil ; Sandu, Florin ; Pana, Gheorghe

  • fYear
    2012
  • fDate
    24-26 May 2012
  • Firstpage
    1000
  • Lastpage
    1005
  • Abstract
    This paper presents some practical considerations for a residential heat pump system: the implementation of the ground loop, the power consumption during the 2010-2011 heating season, a comparison between a heat pump and a gas furnace heating system from the power point of view, the temperature monitoring subsystem and the ground temperature variations for one year period. The main goal of the paper is to demonstrate the heat pump advantages.
  • Keywords
    furnaces; ground source heat pumps; heating; gas furnace heating system; ground loop; ground temperature variations; horizontal collectors; power analysis; power consumption; residential heat pump system; temperature monitoring subsystem; Furnaces; Heat pumps; Land surface temperature; Liquids; Temperature sensors; Water heating; Ground-Loop; Heat Pump; Power Analysis;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Optimization of Electrical and Electronic Equipment (OPTIM), 2012 13th International Conference on
  • Conference_Location
    Brasov
  • ISSN
    1842-0133
  • Print_ISBN
    978-1-4673-1650-7
  • Electronic_ISBN
    1842-0133
  • Type

    conf

  • DOI
    10.1109/OPTIM.2012.6231924
  • Filename