DocumentCode :
2514233
Title :
A method for automatic extraction of striatal structures for dose-finding studies in PET
Author :
Wallius, Esa ; Tohka, Jussi ; Hirvonen, Jussi ; Hietala, Jarmo ; Ruotsalainen, Ulla
Author_Institution :
Inst. of Signal Process., Tampere Univ. of Technol.
Volume :
6
fYear :
2006
fDate :
Oct. 29 2006-Nov. 1 2006
Firstpage :
3189
Lastpage :
3194
Abstract :
The extraction of regions of interest (ROIs) from positron emission tomography (PET) neuroreceptor studies enables the computation of regional binding potential (BP) value of the radioligand in a specific brain structure. When a subject is scanned during baseline (no medication) and intervention (medication) we can compute the receptor occupancy value (a function of BP values). This is important in dose-finding in drug development. In the present study, we have extended an earlier presented automatic method to extract the left and right caudate and putamen for receptor occupancy studies. This is a difficult task even with the baseline images. The task becomes even harder with the intervention images owing to considerably reduced uptake of the tracer. We compared the receptor occupancy values obtained by the introduced automatic method (pairwise dual surface minimization - inner surface) and the traditional, manual ROI drawing and found them to be close to each other. The reproducibility, reliability and validity investigations of BP values showed that the introduced method performed at least as good as manual segmentation. These results support the use of automatic segmentation in receptor occupancy type drug development studies.
Keywords :
automation; dosimetry; image sampling; image segmentation; medical computing; medical control systems; neurophysiology; positron emission tomography; radioisotope imaging; PET neuroreceptor studies; ROI extraction; automatic striatal structure extraction; baseline scanning; brain structure; dose finding studies; drug development studies; intervention scanning; left caudate; pairwise dual surface minimization; positron emission tomography; radioligand; receptor occupancy studies; receptor occupancy value; region of interest; regional BP computation; regional binding potential; right caudate; Biomedical imaging; Brain; Drugs; Image resolution; Image segmentation; Imaging phantoms; Monte Carlo methods; Nuclear and plasma sciences; Positron emission tomography; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2006. IEEE
Conference_Location :
San Diego, CA
ISSN :
1095-7863
Print_ISBN :
1-4244-0560-2
Electronic_ISBN :
1095-7863
Type :
conf
DOI :
10.1109/NSSMIC.2006.353688
Filename :
4179730
Link To Document :
بازگشت