DocumentCode :
2514307
Title :
A Template Based Approach for Automatic Seed Detection in Post-implant CT Images for Prostate Brachytherapy
Author :
Yazdi, Mehran ; GhadarGhadr, Shabnam ; Beaulieu, Luc
Author_Institution :
Dept. of Electr. Eng., Shiraz Univ.
Volume :
6
fYear :
2006
fDate :
Oct. 29 2006-Nov. 1 2006
Firstpage :
3205
Lastpage :
3208
Abstract :
3D reconstruction of implanted seeds is an essential step for post-operative dosimetry in prostate brachytherapy. However, because of the slice thickness and artifacts produced by seeds, large areas will be appeared in computed tomography (CT) images representing many seeds. We propose a new algorithm for the automatic localization and reconstruction of implanted seeds with main focus on localizing connected seeds using a set of binary templates with respect to the shape of artifacts of individual and connected seeds. The results compared with those of fluoroscopic images demonstrate that our algorithm can achieve above 97% detection rate with less than 0.5 mm localization error and reliable orientation accuracy.
Keywords :
automation; brachytherapy; computerised tomography; dosimetry; image recognition; image reconstruction; medical computing; medical control systems; 3D implanted seed reconstruction; artifact shape; automatic localization; automatic reconstruction; automatic seed detection; binary templates; computed tomography; imaging artifacts; post mplant CT images; post operative dosimetry; prostate brachytherapy; template based approach; Brachytherapy; Computed tomography; Detection algorithms; Dosimetry; Image databases; Image reconstruction; Nuclear and plasma sciences; Pixel; Radiography; Shape;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2006. IEEE
Conference_Location :
San Diego, CA
ISSN :
1095-7863
Print_ISBN :
1-4244-0560-2
Electronic_ISBN :
1095-7863
Type :
conf
DOI :
10.1109/NSSMIC.2006.353691
Filename :
4179733
Link To Document :
بازگشت