DocumentCode :
2515435
Title :
Intercomparison of VHF/UHF antenna calibration among Japanese testing Labs.
Author :
Fujii, Katsumi ; Sugiura, Akira ; Yamanaka, Yukio
Author_Institution :
Nat. Inst. of Inf.&Commun. Technol. (NICT), Tokyo, Japan
fYear :
2010
fDate :
12-16 April 2010
Firstpage :
790
Lastpage :
793
Abstract :
Inter-comparison of EMI antenna calibration was conducted among 9 competent organizations in Japan for the frequency range of 30 to 1000 MHz in 2008. The p articipating organizations were NIST, AIST (NMI Japan), commercial testing laboratories and manufacturers. Among them, three types of EMI measurement antennas (tune dipole antenna, biconical antenna, and LPDA) were circulated for antenna calibration. It is found that the antenna factors determined by the participating organizations fall within a range of a standard deviation about ±0.5 dB around the results of AIST and the maximum of the expanded uncertainty (k=2) reaches 1.3 dB for the calibration of a dipole antenna.
Keywords :
VHF antennas; calibration; dipole antennas; electromagnetic interference; EMI antenna calibration; Japanese testing labs; UHF antenna; VHF antenna; dipole antenna; frequency 30 MHz to 1000 MHz; standard deviation; Antenna measurements; Calibration; Dipole antennas; Electromagnetic interference; Frequency; Laboratories; Manufacturing; NIST; Testing; UHF antennas; Antenna calibration; LPDA; biconical antenna; dipole antenna;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility (APEMC), 2010 Asia-Pacific Symposium on
Conference_Location :
Beijing
Print_ISBN :
978-1-4244-5621-5
Type :
conf
DOI :
10.1109/APEMC.2010.5475766