• DocumentCode
    2517228
  • Title

    Diffraction Enhanced Imaging for Analyzing Breast Samples

  • Author

    Rocha, Henrique S. ; Pereira, Gabriela R. ; Faria, Paulo A. ; Kellermann, Guinther ; Mazzaro, Irineu ; Tirao, Germãn A. ; Giles, Carlos M. ; Lopes, Ricardo T.

  • Author_Institution
    Laboratorio de Instrumentacao Nucl., COPPE/UFRJ, Rio de Janeiro
  • Volume
    6
  • fYear
    2006
  • fDate
    Oct. 29 2006-Nov. 1 2006
  • Firstpage
    3936
  • Lastpage
    3939
  • Abstract
    The development of new techniques to diagnostic cancer and other diseases in breast is a world tendency due to the increasing number of breast cancer cases. This work uses the diffraction enhanced imaging (DEI) characteristics to analyze breast tissues details with close attenuation coefficients. An X-ray imaging systems with DEI techniques were developed using synchrotron radiation. The DEI experiment was performed in D10A-XRD2 beamline at the Brazilian Synchrotron-LNLS. The pre-monochromator, upstream of the beamline was adjusted to 10.7 keV. The samples were positioned between two channel-cut (Si-333) in non-dispersive geometry mounted in a double axes diffractometer. A direct conversion water-cooled CCD camera of 1242 pixel times 1152 pixel of 25 mum times 25 mum each was used as a two-dimensional detector in scanning mode. The DEI system can show details in low attenuation tissues based on the contrast imaging obtained by attenuation, refraction gradient and ultra-small angle scatter characteristics. In this work the capacity to observe different types and details in breast tissues structures were investigated.
  • Keywords
    X-ray diffractometers; biological tissues; cancer; diagnostic radiography; mammography; synchrotron radiation; 10.7 keV; Brazilian Synchrotron-LNLS; D10A-XRD2 beamline; X-ray imaging systems; biological tissue; breast cancer; close attenuation coefficient; diffraction enhanced imaging; direct conversion water-cooled CCD camera; diseases; double axes diffractometer; pre-monochromator; synchrotron radiation; Attenuation; Breast cancer; Breast tissue; Diseases; Geometrical optics; Image analysis; Optical imaging; Synchrotron radiation; X-ray diffraction; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2006. IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1095-7863
  • Print_ISBN
    1-4244-0560-2
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2006.353849
  • Filename
    4179891