  • Title

    Experimental application of digital PD measurements to the diagnostics of railway system drives insulating systems

  • Author

    Centurioni, L. ; Coletti, G. ; Guastavino, F. ; Colombo, A.

  • Author_Institution
    Dept. of Electr. Eng., Genoa Univ., Italy
  • fYear
    1998
  • fDate
    22-25 Jun 1998
  • Firstpage
    131
  • Lastpage
    134
  • Abstract
    The present work explores the possibility of introducing, in the service monitoring of electrical drives for railway systems (or for similar transportation systems), a diagnostic tool of the relevant insulating system, based on the digital measurement of partial discharges (PD) by means of PRPDA (Phase Resolved Partial Discharge Analyser) devices. The relevant investigation regarded both new and “aged” (that is having a record of 3500 service hours) asynchronous rotating machines, which, after a specific optimisation of the testing procedure and of the testing circuit, have been subjected to several PD measuring campaigns, run at four different AC voltages. A suitable analysis of the relevant PD data, performed through an “ad hoc” software, allowed to identify several indicators (derived quantities and/or statistical parameters related to the acquired PD patterns) which have a potential for a clear discrimination between new and “aged” insulation. Therefore the results of this preliminary work evidence that a correct application of digital PD measuring techniques can offer a sound basis to develop a tool to monitor the conditions of the insulating system of electrical drives for railways systems
  • Keywords
    ageing; condition monitoring; digital instrumentation; induction motor drives; insulation testing; machine insulation; partial discharge measurement; railways; 1770 V; 2.5 to 4 kV; 700 kVA; AC voltage; ad hoc software; aged insulation; asynchronous rotating machines; condition monitoring; digital PD measurements; electrical drives; phase resolved partial discharge analyser devices; railway system drive insulation diagnostics; service monitoring; statistical parameters; testing procedure optimisation; Circuit testing; Dielectrics and electrical insulation; Drives; Electric variables measurement; Monitoring; Partial discharge measurement; Partial discharges; Phase measurement; Rail transportation; Rotating machines;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Conduction and Breakdown in Solid Dielectrics, 1998. ICSD '98. Proceedings of the 1998 IEEE 6th International Conference on
  • Conference_Location
    Vasteras
  • Print_ISBN
    0-7803-4237-2
  • Type

    conf

  • DOI
    10.1109/ICSD.1998.709243
  • Filename
    709243