Abstract :
Many MEMS devices such as accelerators, gyroscopes, un-cooled infrared sensors, etc. require vacuum packaging. The vacuum maintaining lifetime directly determines the vacuum packaging reliability. This research presented a quantitatively analysis of the relationship between the leak rate and the vacuum maintaining lifetime, and demonstrated the leak rate measurement plays great importance. This paper also explored the application limitations in vacuum packaging using helium spectrometer leak tester to measure the leak rate because the measured leak rate was nonlinear with respect to the actual leak size. According to the fact that the damping coefficient changes with the pressure, a tuning fork crystal chip as a pressure sensor was used to monitor the pressure changes in the package cavity. The leak conductance was also calculated from the pressure tracking data to analyze the leak modes, the molecular flow model and gas desorption model were found to fit the measurement results of leak conductance.
Keywords :
damping; electronics packaging; leak detection; micromechanical devices; pressure sensors; vacuum techniques; vibrations; MEMS; damping coefficient; gas desorption model; helium spectrometer leak tester; leak rate; molecular flow model; pressure sensor; tuning fork crystal chip; vacuum packaging; Gyroscopes; Helium; Infrared sensors; Maintenance; Microelectromechanical devices; Micromechanical devices; Packaging; Semiconductor device measurement; Size measurement; Spectroscopy;
Conference_Titel :
Electronics Packaging Technology Conference, 2008. EPTC 2008. 10th
Conference_Location :
Singapore
Print_ISBN :
978-1-4244-2117-6
Electronic_ISBN :
978-1-4244-2118-3
DOI :
10.1109/EPTC.2008.4763523