DocumentCode
2519431
Title
Voltage index for stationary and transient states
Author
Borrás, Maria-Dolores ; Montano, Juan-Carlos ; Castilla, Manuel ; López, Antonino ; Gutiérrez, Jaime ; Bravo, Juan-Carlos
Author_Institution
Univ. of Seville, Seville, Spain
fYear
2010
fDate
26-28 April 2010
Firstpage
679
Lastpage
684
Abstract
The Fourier Transform analysis is able to estimate the amplitude and frequency of signals under stationary conditions. For transient or aperiodic signals the Fourier analysis is unable to obtain accurate results and a joint time-frequency analysis must be used to provide simultaneous time and frequency information of transient intervals. A voltage quality index is proposed for evaluation of both the stationary and transient quality aspects of electrical signals. The widely used total harmonic distortion index (THD) is redefined in this paper to include harmonics, oscillatory transients, voltage sags and swells. The new index is defined between the 0-1 range.
Keywords
Fourier transforms; harmonic distortion; power supply quality; time-frequency analysis; transient analysis; Fourier transform analysis; THD; aperiodic signals; oscillatory transients; stationary-transient states; time-frequency analysis; total harmonic distortion index; voltage quality index; voltage sags; voltage swells; Amplitude estimation; Fourier transforms; Frequency estimation; Information analysis; Power quality; Signal analysis; Time frequency analysis; Total harmonic distortion; Transient analysis; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
MELECON 2010 - 2010 15th IEEE Mediterranean Electrotechnical Conference
Conference_Location
Valletta
Print_ISBN
978-1-4244-5793-9
Type
conf
DOI
10.1109/MELCON.2010.5475997
Filename
5475997
Link To Document