DocumentCode :
2520302
Title :
May the capacitance of power cables be an aging indicator?
Author :
Savin, S. ; Ait-Amar, S. ; Roger, D. ; Vélu, G.
Author_Institution :
Univ. Lille Nord de France, Lille, France
fYear :
2011
fDate :
16-19 Oct. 2011
Firstpage :
60
Lastpage :
63
Abstract :
The presented paper concerns the insulation of cables providing the link between the converters and electrical machines in aircraft. It focuses on thermal aging tests performed on cables with the analysis of the capacitance variation. The tests were conducted on samples of a three-wire shielded cable, insulated with polyimide and polytetrafluoroethylene (PTFE). This study shows that the capacitance between the conductors of a cable is correlated with the aging of its electrical insulation.
Keywords :
ageing; indicators; insulation testing; power cable insulation; power cable testing; power convertors; PTFE; aging indicator; aircraft; capacitance variation analysis; conductors; converters; electrical insulation ageing; electrical machines; polyimide insulatio; polytetrafluoroethylene; power cable capacitance; thermal aging tests; three-wire shielded cable; Aging; Cable insulation; Cable shielding; Capacitance; Capacitance measurement; Power cables; Wires;