DocumentCode :
2520319
Title :
Aging effects on the AC motor windings: A correlation between the variation of turn-to-turn capacitance and the PDIV
Author :
Savin, S. ; Ait-Amar, S. ; Roger, D. ; Vélu, G.
Author_Institution :
Univ. Lille Nord de France, Lille, France
fYear :
2011
fDate :
16-19 Oct. 2011
Firstpage :
64
Lastpage :
67
Abstract :
The presented paper focuses on monitoring of turn-to-turn insulation quality. It is based on the measure of the variation of the winding turn-to-turn capacitance and the Partial Discharge Inception Voltage (PDIV). The test methods is defined and described. Twisted pairs of three different diameters of enameled wires were tested. The PDIV is measured with an adequate system properly calibrated to minimize background noise to an acceptable value. Finally, it is shown an increased capacitance and a reduction PDIV between aging cycles. The correlation of these two parameters opens perspectives for preventive maintenance applications.
Keywords :
AC motors; ageing; machine insulation; machine windings; partial discharges; AC motor windings; PDIV; aging cycles; aging effects; background noise minimization; partial discharge inception voltage; preventive maintenance applications; turn-to-turn capacitance; turn-to-turn insulation quality; Aging; Capacitance; Capacitance measurement; Insulation; Partial discharges; Windings; Wires;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation and Dielectric Phenomena (CEIDP), 2011 Annual Report Conference on
Conference_Location :
Cancun
ISSN :
0084-9162
Print_ISBN :
978-1-4577-0985-2
Type :
conf
DOI :
10.1109/CEIDP.2011.6232597