DocumentCode :
2522230
Title :
Comparison of ultrasonic, electrical and UHF characteristics of partial discharge emission in oil/paper insulation systems
Author :
Cavallini, Andrea ; Ramos, Carlos Gustavo Azcarraga ; Montanari, Gian Carlo ; Rubio-Serrano, Jesus ; Garcia-Souto, Jose A.
Author_Institution :
Dipt. di Ing. Elettr., Univ. di Bologna, Bologna, Italy
fYear :
2011
fDate :
16-19 Oct. 2011
Firstpage :
440
Lastpage :
443
Abstract :
In this paper, partial discharge measurements on artificial specimens simulating corona, surface and internal partial discharge in paper/oil insulation systems are discussed. Focus is made on a comparative analysis of signals derived through both conventional (conducted electrical signals) and unconventional (acoustic and UltraHigh Frequency emission) techniques. The results indicate that unconventional techniques can provide evidence of partial discharge activity, but are not sufficient to assess the severity of the detected phenomenon. This requires apparent charge measurements conducted through conventional detectors. In the case streamers are observed, narrowband detection (with bandwidths below 50 kHz) must be used to get an accurate estimate of apparent charges.
Keywords :
corona; partial discharge measurement; power transformer insulation; UHF characteristics; apparent charge measurements; comparative analysis; corona; electrical characteristics; oil-paper insulation systems; partial discharge emission; power transformers; ultrasonic characteristics; Acoustics; Bandwidth; Corona; Electrodes; Partial discharges; Sensors; UHF measurements;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation and Dielectric Phenomena (CEIDP), 2011 Annual Report Conference on
Conference_Location :
Cancun
ISSN :
0084-9162
Print_ISBN :
978-1-4577-0985-2
Type :
conf
DOI :
10.1109/CEIDP.2011.6232689
Filename :
6232689
Link To Document :
بازگشت