DocumentCode
2523612
Title
Pre-breakdown current in long point-plane transformer oil gaps with insulating barrier under AC voltage
Author
Guerbas, F. ; Boubakeur, A. ; Beroual, A.
Author_Institution
Lab. de Haute Tension, Ecole Nat. Polytech., Algiers, Algeria
fYear
2011
fDate
16-19 Oct. 2011
Firstpage
744
Lastpage
747
Abstract
In this paper we present results of carried out investigations on the influence of insulating barriers on AC prebreakdown current of long point-plane transformer oil gaps up to 12cm. The insertion of an insulating barrier leads to an important prebreakdown current decrease. The barrier acts as a geometrical and electrostatic obstacle for the disruptive discharge. We present in the paper a comparison between the prebreakdown current in the system with barrier to that one without barrier. We have considered the parameters of the barrier such as its position between the electrodes, and its nature. We observe that the evolution of the pre-breakdown current versus the applied voltage has a capacitive behavior. The equivalent impedance of the oil gap is deduced from the experimental current-voltage characteristics.
Keywords
electric breakdown; electrodes; electrostatics; power transformer insulation; transformer oil; AC pre-breakdown current; AC voltage; capacitive behavior; disruptive discharge; electrode; electrostatic obstacle; experimental current-voltage characteristic; geometrical obstacle; insulating barrier insertion; long point-plane transformer oil gap; oil gap impedance; Discharges; Electrodes; Impedance; Oil insulation; Power transformer insulation; long point-plane gaps; pre-breakdown current; transformer oil;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation and Dielectric Phenomena (CEIDP), 2011 Annual Report Conference on
Conference_Location
Cancun
ISSN
0084-9162
Print_ISBN
978-1-4577-0985-2
Type
conf
DOI
10.1109/CEIDP.2011.6232763
Filename
6232763
Link To Document