DocumentCode
2525207
Title
Study on the damage of the floating roof due to thermal stress
Author
Hirokawa, Yoshihiro ; Yamada, Minoru ; Nishi, Haruki ; Zama, Shinsaku ; Hatayama, Ken
Author_Institution
R&D Div., Nat. Res. Inst. of Fires & Disasters (NRIFD), Chofu, Japan
fYear
2010
fDate
10-12 Sept. 2010
Firstpage
560
Lastpage
564
Abstract
Several cracks were found on some actual floating roof of the crude oil tank in southern Japan. We assumed that one of causes is due to thermal stress during the day. In order to figure out whether the thermal stress could cause damages on the floating roof, strain and temperature were measured on the actual floating roof by using optical fiber gauges. Furthermore, thermal stress analysis and fracture possibility estimation were also carried out.
Keywords
crude oil; fracture; roofs; strain measurement; tanks (containers); temperature measurement; thermal stress cracking; cracks; crude oil tank; floating roof; fracture possibility estimation; optical fiber gauges; strain measurement; temperature measurement; thermal stress; thermal stress analysis; Heating; Probabilistic logic; Seismic measurements; Steel; Stress; Thickness measurement; Crack; FEM; Floating roof; Fracture probability; Measurement; Oil storage tank; Opical fiber gauge; Thermal stress analysis; component;