Title :
The design and performance of 150-MW S-band klystrons
Author :
Sprehn, D. ; Phillips, R.M. ; Caryotakis, G.
Author_Institution :
Linear Accel. Center, Stanford Univ., CA, USA
Abstract :
As part of an international collaboration, the Stanford Linear Accelerator Center (SLAC) klystron group has designed, fabricated and tested a 60 Hz, 3 /spl mu/s, 150 MW klystron built for Deutsches Elektronen Synchrotron (DESY). A test diode with a 535 kV, 700 A electron beam was constructed to verify the gun operation. The first klystron was built and successfully met design specifications. This paper discusses design issues and experimental results of the diode and klystron including the suppression of gun oscillations.<>
Keywords :
diodes; electromagnetic oscillations; electron guns; electron tube testing; klystrons; 150 MW; 3 mus; 477 MHz to 11.424 GHz; 535 kV; 700 A; DESY; Deutsches Elektronen Synchrotron; S-band klystron; Stanford Linear Accelerator Center; design issues; diode; electron beam; gun operation; gun oscillation suppression; Anodes; Cathodes; Diodes; Electrodes; Klystrons; Linear accelerators; Seals; Space vector pulse width modulation; Structural beams; Testing;
Conference_Titel :
Electron Devices Meeting, 1994. IEDM '94. Technical Digest., International
Conference_Location :
San Francisco, CA, USA
Print_ISBN :
0-7803-2111-1
DOI :
10.1109/IEDM.1994.383303