  • Title

    Measuring jitter of high speed data channels using undersampling techniques

  • Author

    Dalal, Wajih ; Rosenthal, Daniel

  • Author_Institution
    Schlumberger Autom. Test Equip., San Jose, CA, USA
  • fYear
    1998
  • fDate
    18-23 Oct 1998
  • Firstpage
    814
  • Lastpage
    818
  • Abstract
    Jitter is a critical parameter in high speed data communication channels. A new jitter measurement technique utilizing a high bandwidth undersampling voltage measurement instrument is presented. This type of undersampling instrument is common in mixed-signal ATE. The advantages of this new technique over other traditional jitter measurement techniques are: bandwidth, ease of use, and throughput
  • Keywords
    automatic test equipment; data communication equipment; digital communication; jitter; signal sampling; telecommunication channels; telecommunication equipment testing; voltage measurement; high bandwidth voltage measurement instrument; high speed data channels; jitter measurement technique; mixed-signal ATE; undersampling techniques; Bandwidth; Circuits; Clocks; Firewire; Instruments; Jitter; Phase locked loops; Time measurement; Transmitters; Velocity measurement;