DocumentCode :
2527230
Title :
Comparative tests of power quality analyzers - harmonic distortion1
Author :
Chmielowiec, K. ; Zietek, M. ; Piatek, K. ; Firlit, A. ; Szkoda, R. ; Balawender, P.
Author_Institution :
Dept. of Electr. Drive & Ind. Equip., AGH Univ. of Sci. & Technol., Krakow, Poland
fYear :
2012
fDate :
17-20 June 2012
Firstpage :
307
Lastpage :
312
Abstract :
This paper describes a laboratory-based comparison of power quality class A analyzers, with respect to voltage harmonic distortion measurements. The tested measuring instruments were designed in accordance to the requirements of the IEC 61000-4-30 standard. The purpose of these tests was to assess the dispersion of results of analyzers connected to a common measuring point. The expectation is that simultaneous measurements of the same voltage signal should result in a readings dispersion not greater than ±5% of the measured value. The described tests are part of a complex evaluation of metrological properties of power quality analyzers carried out at the AGH University of Science and Technology, Krakow. Detailed results of harmonic tests, comparisons, and conclusions are presented.
Keywords :
harmonic distortion; power supply quality; voltage measurement; AGH University of Science and Technology; harmonic tests; lEC 61000-4-30 standard; laboratory-based comparison; metrological properties; power quality class A analyzers; readings dispersion; voltage harmonic distortion measurements; voltage signal; Laboratories; Voltage measurement; Harmonic Distortion; Power Quality; Voltage Measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Harmonics and Quality of Power (ICHQP), 2012 IEEE 15th International Conference on
Conference_Location :
Hong Kong
ISSN :
1540-6008
Print_ISBN :
978-1-4673-1944-7
Type :
conf
DOI :
10.1109/ICHQP.2012.6381286
Filename :
6381286
Link To Document :
بازگشت