DocumentCode :
2530830
Title :
Fast detection of open-switch fault in cascaded H-Bridge multilevel converter
Author :
Shahbazi, Mahmoud ; Zolghadri, MohammadReza
Author_Institution :
Center of Excellence in Power Syst. Manage. & Control (CEPSMC), Sharif Univ. of Technol., Tehran, Iran
fYear :
2015
fDate :
3-4 Feb. 2015
Firstpage :
538
Lastpage :
543
Abstract :
Cascaded H-Bridge converter has recently been utilized in different high-power applications due to its modular and simple structure. In order to have a balanced operation after a fault occurrence in this converter, it is necessary to detect the switch fault and its location. In this paper, a fast power switch fault detection method is presented to identify the fault and its location. Only one voltage measurement per phase is required by this method, and the fault detection is faster compared to the existing methods. Moreover, it is easy for implementation on an FPGA device, due to the use of simple math, relational and state machine blocks. The proposed method is verified by computer simulations.
Keywords :
convertors; fault diagnosis; field programmable gate arrays; power semiconductor switches; voltage measurement; FPGA; cascaded H-bridge multilevel converter; computer simulations; fast power switch fault detection; open-switch fault; voltage measurement; Computational modeling; Computers; Field programmable gate arrays; Ice; Switches; Power switch fault detection; cascaded H-bridge converter Insulated Gate Bipolar Transistor (IGBT); multilevel converter; open-switch fault;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics, Drives Systems & Technologies Conference (PEDSTC), 2015 6th
Conference_Location :
Tehran
Print_ISBN :
978-1-4799-7652-2
Type :
conf
DOI :
10.1109/PEDSTC.2015.7093332
Filename :
7093332
Link To Document :
بازگشت