Title :
Measurement and calculation of doses in and around north-west labyrinth in TFTR test cell shielding for D-T operation
Author :
Kumar, Ajit ; Abdou, Mohamed A. ; Egglestori, J. ; Kugel, Henry W. ; Ascione, George ; Elwood, Stephen
Author_Institution :
Sch. of Eng. & Appl. Sci., California Univ., Los Angeles, CA, USA
fDate :
30 Sep-5 Oct 1995
Abstract :
TFTR test cell has a major penetration that exists on the inner side of the north-west corner of the test cell wall. There is no known direct line of sight from the plasma source to the door. The biological doses were measured at various locations inside both the legs of the labyrinth, in addition to, scattered locations on outer segments of the labyrinth facing the TFTR D-T plasma. In addition, six sets of activation foil detectors were placed covering the south-to-north leg, labyrinth entrance, and west-to-east leg. The doses have been calculated using 3-D Monte Carlo code MCNP with ENDF/B-VI. The calculations reproduce the broad features of the measured data. However, we find significant differences in the calculations for a number of locations. The possible reasons for the differences are discussed
Keywords :
Monte Carlo methods; deuterium; dosimetry; fusion reactor fuel; fusion reactor operation; nuclear engineering computing; shielding; tritium; 3D Monte Carlo code; D-T; D-T operation; ENDF/B-VI code; MCNP code; TFTR test cell shielding; activation foil detectors; biological doses; labyrinth entrance; major penetration; north-west labyrinth; south-to-north leg; west-to-east leg; Biological information theory; Detectors; Leg; Libraries; Neutrons; Nuclear and plasma sciences; Plasma applications; Plasma measurements; Plasma sources; Testing;
Conference_Titel :
Fusion Engineering, 1995. SOFE '95. Seeking a New Energy Era., 16th IEEE/NPSS Symposium
Conference_Location :
Champaign, IL
Print_ISBN :
0-7803-2969-4
DOI :
10.1109/FUSION.1995.534303