DocumentCode :
2531520
Title :
Augmented heat transfer in rectangular duct with angled Z-shaped ribs
Author :
Pimsarn, Monsak ; Sriromreun, Parkpoom ; Promvonge, Pongjet
Author_Institution :
Sch. of Mech. Eng., King Mongkut´´s Inst. of Technol., Bangkok, Thailand
fYear :
2010
fDate :
2-4 June 2010
Firstpage :
1
Lastpage :
7
Abstract :
An experiment is focused on the design of the suitable ribs used for enhancing heat transfer in a rectangular duct heat exchanger by using wall heat transfer (Nusselt number), friction loss (friction factor) and thermal performance (thermal enhancement factor) data. The Z-shaped ribs were set on the rectangular duct at 30°, 45° and 60° and flat rib was set at 90° relative to the air flow direction. Reynolds numbers studied ranging from 5000 to 25,000 in the test section. The rectangular duct has aspect ratio, AR = 10 and height, H = 30 mm with the Z-rib height (e), e/H = 0.2 and the rib pitch (P), P/H = 3. The ribs were fitted in Z-shape (Z-rib) aligned in series on the whole area of the upper plate. The results of the Z-ribs show the significant increase in heat transfer rate and friction loss over the smooth channel. The 45° Z-rib provides the highest increase in the heat transfer rate and the best thermal performance.
Keywords :
ducts; friction; heat exchangers; heat transfer; turbulence; Nusselt number; Reynolds numbers; air flow direction; friction factor; friction loss; heat exchanger; heat transfer; rectangular ducts; thermal enhancement factor; z-shape ribs; Educational institutions; Heating; Inverters; Nusselt number; angle rib; channel flow; enhanced heat transfer; rib;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Energy and Sustainable Development: Issues and Strategies (ESD), 2010 Proceedings of the International Conference on
Conference_Location :
Chiang Mai
Print_ISBN :
978-1-4244-8563-5
Type :
conf
DOI :
10.1109/ESD.2010.5598858
Filename :
5598858
Link To Document :
بازگشت