Abstract :
This work presents the first fabricated and characterized MEMS in polycrystalline silicon-germanium (poly-SiGe) for biosensing applications. The devices, clamped-clamped microresonators, combine the possibility of above-IC MEMS-CMOS integration with a stiction-free design that enables biomolecule mass sensing in air. By perforating the resonant beam with square or hexagonal holes, a higher surface-to-volume ratio is achieved leading to an increased relative frequency shift for a certain analyte surface density. A minimum detectable mass of ~2pg in air was calculated. A mass sensing test was performed on these perforated devices by immobilization of biotin and the extraction of the resulting resonance frequency shift.
Keywords :
CMOS integrated circuits; Ge-Si alloys; bioMEMS; biosensors; MEMS-CMOS integration; SiGe; analyte surface density; biomolecule mass sensing; biosensors; biotin; mass sensing test; monolithic integration; relative frequency shift; resonant beam; stiction-free poly-silicon-germanium resonator; surface-to-volume ratio; Coatings; Electrodes; Frequency measurement; Resonant frequency; Sensors; Silicon germanium; Surface treatment; Monolithic integration; SiGe; biosensors; resonators;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Solid-State Sensors, Actuators and Microsystems Conference (TRANSDUCERS), 2011 16th International
Conference_Location :
Beijing
ISSN :
Pending
Print_ISBN :
978-1-4577-0157-3
Type :
conf
DOI :
10.1109/TRANSDUCERS.2011.5969323
Filename :
5969323
Link To Document :
بازگشت