• DocumentCode
    2535259
  • Title

    On the use of gap metric for model selection in multilinear model-based control

  • Author

    Galán, O. ; Romagnoli, J.A. ; Arkun, Y. ; Palazoglu, A.

  • Author_Institution
    Lab. of Process Syst. Eng., Sydney Univ., NSW, Australia
  • Volume
    6
  • fYear
    2000
  • fDate
    2000
  • Firstpage
    3742
  • Abstract
    One way to design the control of a nonlinear system is to use a set of linear models that are close to the nonlinear system. This gives rise to a need to define the concept of closeness. Since systems can be visualized as input-output operators, a natural distance concept would be the induced operator norm. Yet, the norm cannot be generalized as a distance measure. The aim of this paper is to discuss the application of a distance measure between systems, the gap metric, in order to select a reduced set of models that contain nonredundant process information for robust stabilization of feedback systems based on multimodel controller design
  • Keywords
    control system synthesis; feedback; nonlinear control systems; robust control; I/O operators; approximate models; distance measure; feedback systems; gap metric; induced operator norm; input-output operators; linear models; model selection; multilinear model-based control; multimodel controller design; nonlinear system control design; nonredundant process information; robust stabilization; Chemical engineering; Control systems; Feedback; Laboratories; Linear systems; Nonlinear control systems; Nonlinear systems; Robust control; Robust stability; Systems engineering and theory;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    American Control Conference, 2000. Proceedings of the 2000
  • Conference_Location
    Chicago, IL
  • ISSN
    0743-1619
  • Print_ISBN
    0-7803-5519-9
  • Type

    conf

  • DOI
    10.1109/ACC.2000.876920
  • Filename
    876920