DocumentCode :
2535998
Title :
Measurement of Discharge Currents due to Human-ESD
Author :
Taka, Yoshinori ; Kagawa, Yoshihisa ; Fujiwara, Osamu
Author_Institution :
Nagoya Inst. of Technol., Nagoya
fYear :
2007
fDate :
23-26 Oct. 2007
Firstpage :
43
Lastpage :
46
Abstract :
Using a 12-GHz digital oscilloscope, we have measured discharge currents through a fingertip or a hand-held metal bar from a charged human body with a charge voltage of 600 V, and have compared their discharge waveforms in conjunction with the corresponding discharge voltages, which were derived from our previously proposed equivalent circuit model.
Keywords :
digital storage oscilloscopes; electrostatic discharge; equivalent circuits; waveform analysis; digital oscilloscope; discharge currents; discharge voltages; discharge waveforms; equivalent circuit model; human electrostatic discharge; Current measurement; Human-ESD; discharge current; fingertip; hand-held metal bar; wideband measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility, 2007. EMC 2007. International Symposium on
Conference_Location :
Qingdao
Print_ISBN :
978-1-4244-1371-3
Type :
conf
DOI :
10.1109/ELMAGC.2007.4413427
Filename :
4413427
Link To Document :
بازگشت