• DocumentCode
    2536017
  • Title

    Transfer Impedance of SMA Receptacle as Wideband Measurement Electrode for Discharge Current from Charged Human

  • Author

    Kagawa, Yoshihisa ; Taka, Yoshinori ; Fujiwara, Osamu

  • Author_Institution
    Nagoya Inst. of Technol., Nagoya
  • fYear
    2007
  • fDate
    23-26 Oct. 2007
  • Firstpage
    47
  • Lastpage
    50
  • Abstract
    We have derived a transfer impedance of an SMA receptacle as a wideband measurement electrode being used for discharge currents from a charged human, and have measured its frequency characteristics from 300 kHz to 20 GHz. With a 12 GHz digital oscilloscope, measurement of discharge currents through a hand-held metal bar from a charged human was also made, and thereby the injected currents on the SMA receptacle were reconstructed from the measured transfer impedance.
  • Keywords
    bioelectric phenomena; biomedical measurement; electric current measurement; electric impedance; electromagnetic interference; SMA receptacle; charged human; digital oscilloscope; discharge current; frequency 300 kHz to 20 GHz; frequency characteristics; hand-held metal bar; transfer impedance; wideband measurement electrode; Aluminum; Current measurement; Electrodes; Electrostatic discharge; Frequency; Humans; Impedance measurement; Oscilloscopes; Voltage; Wideband; Charged human; SMA receptacle; discharge current; transfer impedance;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 2007. EMC 2007. International Symposium on
  • Conference_Location
    Qingdao
  • Print_ISBN
    978-1-4244-1371-3
  • Type

    conf

  • DOI
    10.1109/ELMAGC.2007.4413428