Title :
The Spatial Effect and Compensation of Current Sensor Gain Deviation for Three-phase Three-wire Systems
Author :
Harke, Michael C. ; Lorenz, Robert D.
Author_Institution :
Hamilton Sundstrand, 4747 Harrison Ave, Rockford, IL 61108 USA
fDate :
Feb. 25 2007-March 1 2007
Abstract :
Current sensor errors affect torque control and saliency-tracking position estimation of ac machines. A spatial model of current sensor gain deviation is developed and used to determine its affect on a general current measurement, verified with experimental data. Three current sensors enable a three-phase three-wire system to compensate for current sensor gain deviation independent of additional machine saliencies. Simulation and experimental results confirm the current sensor gain deviation compensation algorithm.
Keywords :
AC machines; Circuits; Current measurement; Error correction; Gain measurement; Phase estimation; Phase measurement; Sensor phenomena and characterization; Sensor systems; Torque control;
Conference_Titel :
Applied Power Electronics Conference, APEC 2007 - Twenty Second Annual IEEE
Conference_Location :
Anaheim, CA, USA
Print_ISBN :
1-4244-0713-3
DOI :
10.1109/APEX.2007.357550