• DocumentCode
    2540612
  • Title

    A Direct Peak DC-link Boost Voltage Control Strategy in Z-Source Inverter

  • Author

    Ding, Xinping ; Qian, Zhaoming ; Yang, Shuitao ; Cui, Bin ; Peng, Fangzheng

  • Author_Institution
    College of Electrical Engineering, Zhejiang University, Hangzhou, China, 310027
  • fYear
    2007
  • fDate
    Feb. 25 2007-March 1 2007
  • Firstpage
    648
  • Lastpage
    653
  • Abstract
    A PID controller for direct peak dc-link boost voltage in Z-source inverter has been introduced. With this technique a high-performance inverter output voltage can be achieved with an excellent transient performance which enhances the rejection of disturbance, including the input voltage ripple and load current variation, and have good ride-through for voltage-sags. The peak dc-link voltage direct sensing & scaling method, and modified modulation strategy have been described, which simplify the controller design, improve the transient response and decrease the voltage stress across the switches. The proposed technique was verified on a 10-kW prototype. The experimental results meet the simulation and analysis results very well.
  • Keywords
    Capacitors; Circuits; Dynamic voltage scaling; Inverters; Stress; Switches; Three-term control; Transient response; Virtual colonoscopy; Voltage control; PID controller; Z-source inverter; buck-boost; shoot-through;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Applied Power Electronics Conference, APEC 2007 - Twenty Second Annual IEEE
  • Conference_Location
    Anaheim, CA, USA
  • ISSN
    1048-2334
  • Print_ISBN
    1-4244-0713-3
  • Type

    conf

  • DOI
    10.1109/APEX.2007.357583
  • Filename
    4195787