Time-resolved measurements of thermal loads on the FTU limiter
Author :
Franzoni, G. ; Zanino, R.
Author_Institution :
Dipartimento di Energetica, Politecnico di Torino, Italy
fDate :
30 Sep-5 Oct 1995
Abstract :
A methodology for measuring instantaneous thermal loads on a portion of the Frascati Tokamak Upgrade (FTU) poloidal limiter was developed; such a methodology is based upon the processing of experimental data recorded by thermocouples and an infra red detector. By a proper calibration procedure, the instantaneous surface temperature of a portion of the limiter can be obtained; the deconvolution of the time-resolved limiter surface temperature provides time-resolved thermal loads. In this paper the apparatus is described and some examples of elaborated data are given
Keywords :
Tokamak devices; calibration; fusion reactor instrumentation; fusion reactor limiters; fusion reactors; temperature measurement; thermocouples; FTU limiter; Frascati Tokamak Upgrade; calibration; infra red detector; instantaneous surface temperature; instantaneous thermal loads; poloidal limiter; thermocouples; time-resolved limiter surface temperature; time-resolved measurements; time-resolved thermal loads; Calibration; Detectors; Gunshot detection systems; Plasma measurements; Plasma temperature; Rough surfaces; Signal detection; Surface roughness; Temperature measurement; Thermal loading;