  • Abstract
    Knowledge of moisture content in raw coal feed to a power plant coal mill is of importance for efficient operation of the mill. The moisture is commonly measured approximately once a day using offline chemical analysis methods; however, it would be advantageous for the dynamic operation of the plant if an on-line estimate were available. In this paper we such propose an on-line estimator (an extended Kalman filter) that uses only existing measurements. The scheme is tested on actual coal mill data collected during a one-month operating period, and it is found that the daily measured moisture content agrees with the estimates.
  • Keywords
    Kalman filters; chemical analysis; coal; moisture measurement; signal processing equipment; thermal power stations; chemical analysis methods; coal moisture estimation; extended Kalman filter; power plant mills; Automatic control; Automation; Chemical analysis; Feeds; Milling machines; Moisture control; Moisture measurement; Power generation; Surface treatment; Temperature;