DocumentCode
2543342
Title
Testing controls to mitigate fatigue loads in the controls Advanced Research Turbine
Author
Wright, Alan D. ; Fingersh, Lee J. ; Stol, Karl A.
Author_Institution
Nat. Renewable Energy Lab., Golden, CO, USA
fYear
2009
fDate
24-26 June 2009
Firstpage
1275
Lastpage
1282
Abstract
Wind turbines are complex, nonlinear, dynamic systems forced by aerodynamic, gravitational, centrifugal, and gyroscopic loads. The aerodynamics of wind turbines is nonlinear, unsteady, and complex. Turbine rotors are subjected to a complicated three-dimensional (3D) turbulent wind inflow field with imbedded coherent vortices that drive fatigue loads and reduce lifetime. Design of control algorithms for wind turbines must account for multiple control objectives. Future large multi-megawatt turbines must be designed with lighter weight structures, using active controls to mitigate fatigue loads, maximize energy capture, and add active damping to maintain stability for these dynamically active structures operating in a complex environment. Researchers at the National Renewable Energy Laboratory are designing, implementing, and testing advanced controls to maximize energy extraction and reduce structural dynamic loads. These control designs are based on a linear model of the turbine that is generated by specialized modeling software. This paper describes testing of a control algorithm to mitigate blade, tower, and drivetrain loads using advanced state-space control methods. The controller uses independent blade pitch to regulate the turbine´s speed in Region 3, mitigate the effects of shear across the rotor disk, and add active damping to the tower´s first fore-aft bending mode. Additionally, a separate generator torque control loop is designed to add active damping to the tower´s first side-side mode and the first drivetraintorsion mode. This paper discusses preliminary implementation and field tests of this controller in the Controls Advanced Research Turbine at the National Renewable Energy Laboratory. Also included are preliminary comparisons of the performance of this controller to results from a typical baseline Proportional-Integral-Derivative controller designed with just Region 3 speed regulation as the goal.
Keywords
aerodynamics; damping; fatigue; rotors; three-term control; torque control; wind turbines; 3D turbulent wind inflow field; active damping; advanced research turbine; aerodynamics; fatigue load; proportional-integral-derivative controller; state-space control; torque control; turbine rotor; wind turbine; Aerodynamics; Blades; Damping; Fatigue; Laboratories; Poles and towers; Region 3; Renewable energy resources; Testing; Wind turbines;
fLanguage
English
Publisher
ieee
Conference_Titel
Control and Automation, 2009. MED '09. 17th Mediterranean Conference on
Conference_Location
Thessaloniki
Print_ISBN
978-1-4244-4684-1
Electronic_ISBN
978-1-4244-4685-8
Type
conf
DOI
10.1109/MED.2009.5164722
Filename
5164722