• DocumentCode
    2543912
  • Title

    Development of the active neutron-based interrogation system with D-D neutron source for the detection of special nuclear materials

  • Author

    Misawai, Tsuyoshi ; Yamaguchi, Yoshio ; Yagi, Takeshi ; Takahashi, Y. ; Cheol Ho Pyeon ; Masuda, Kohji ; Kajiwara, Toshiya ; Ohgaki, H.

  • Author_Institution
    Res. Reactor Inst., Kyoto Univ., Kumatori, Japan
  • fYear
    2012
  • fDate
    Oct. 27 2012-Nov. 3 2012
  • Firstpage
    114
  • Lastpage
    117
  • Abstract
    The detection of hidden special nuclear materials (SNMs) is important issue for nuclear security. For this purpose, we have been developing an active neutron-based interrogation system combined with a D-D fusion neutron source, which is a compact discharge-type fusion neutron source called IEC (Inertial-Electrostatic Confinement Fusion) device and provides pulsed neutrons of 2.45MeV. The neutron noise analysis method and the detection of high energy fission neutron spectrum are employed for detection of SNMs.
  • Keywords
    national security; neutron detection; neutron sources; nuclear materials safeguards; radioactivity measurement; D-D fusion neutron source; IEC device; Inertial-Electrostatic Confinement Fusion; active neutron-based interrogation system; compact discharge-type fusion neutron source; electron volt energy 2.45 MeV; high energy fission neutron spectrum; neutron noise analysis method; nuclear security; pulsed neutrons; special nuclear materials;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
  • Conference_Location
    Anaheim, CA
  • ISSN
    1082-3654
  • Print_ISBN
    978-1-4673-2028-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2012.6551072
  • Filename
    6551072