DocumentCode
2543912
Title
Development of the active neutron-based interrogation system with D-D neutron source for the detection of special nuclear materials
Author
Misawai, Tsuyoshi ; Yamaguchi, Yoshio ; Yagi, Takeshi ; Takahashi, Y. ; Cheol Ho Pyeon ; Masuda, Kohji ; Kajiwara, Toshiya ; Ohgaki, H.
Author_Institution
Res. Reactor Inst., Kyoto Univ., Kumatori, Japan
fYear
2012
fDate
Oct. 27 2012-Nov. 3 2012
Firstpage
114
Lastpage
117
Abstract
The detection of hidden special nuclear materials (SNMs) is important issue for nuclear security. For this purpose, we have been developing an active neutron-based interrogation system combined with a D-D fusion neutron source, which is a compact discharge-type fusion neutron source called IEC (Inertial-Electrostatic Confinement Fusion) device and provides pulsed neutrons of 2.45MeV. The neutron noise analysis method and the detection of high energy fission neutron spectrum are employed for detection of SNMs.
Keywords
national security; neutron detection; neutron sources; nuclear materials safeguards; radioactivity measurement; D-D fusion neutron source; IEC device; Inertial-Electrostatic Confinement Fusion; active neutron-based interrogation system; compact discharge-type fusion neutron source; electron volt energy 2.45 MeV; high energy fission neutron spectrum; neutron noise analysis method; nuclear security; pulsed neutrons; special nuclear materials;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
Conference_Location
Anaheim, CA
ISSN
1082-3654
Print_ISBN
978-1-4673-2028-3
Type
conf
DOI
10.1109/NSSMIC.2012.6551072
Filename
6551072