• DocumentCode
    2544199
  • Title

    Study of a 10B-based multi-blade detector for neutron scattering science

  • Author

    Buffet, J.C. ; Correa, Javier ; Van Esch, Patrick ; Guerard, Bruno ; Khaplanov, Anton ; Piscitelli, Francesco

  • Author_Institution
    Inst. Laue-Langevin (ILL), Grenoble, France
  • fYear
    2012
  • fDate
    Oct. 27 2012-Nov. 3 2012
  • Firstpage
    171
  • Lastpage
    175
  • Abstract
    The main goal in neutron reflectometry instruments is to achieve a high angular resolution and high counting rates. Although 3He shortage affects scientific research in neutron scattering science due to its wide use in detectors as neutron converter; this is not the main issue for neutron reflectometry application where detector sizes are generally moderate. Indeed 3He detectors are instead limited in spatial resolution. To reduce the particles traces and thereby increase the spatial resolution those detectors are operated at high quencher gas pressure, resulting in mechanical constraints. A promising alternative, to accomplish these goals, is to exploit solid 10B-films employed in a proportional gas chamber. The challenge with this technique is to attain a suitable detection efficiency. This can be achieved by operating the 10B conversion layer at grazing angle relative to the incoming neutron direction. The Multi-Blade design is based on this operational principle and it is conceived to be modular in order to be adaptable to different applications. A prototype has been developed at ILL and the results obtained on our monochromatic test beam line are presented here. A significant concern in a modular design is the uniformity of detector response: several effects might contribute to degrade the uniformity and they have to be taken into account in the detector concept: overlap between different substrates, coating uniformity, substrate flatness, parallax errors, etc. A simulation has been developed to address these problems.
  • Keywords
    neutron detection; proportional counters; 10B conversion layer; 10B-based multiblade detector; 3He detectors; 3He shortage; ILL; coating uniformity; detection efficiency; detector response; detector sizes; grazing angle; high angular resolution; high counting rates; high quencher gas pressure; incoming neutron direction; mechanical constraints; modular design; monochromatic test beam line; multiblade design; neutron converter; neutron reflectometry application; neutron reflectometry instruments; neutron scattering science; operational principle; parallax errors; particle traces; proportional gas chamber; solid 10B-films; spatial resolution; substrate flatness; 10B; 3He-shortage; inclined geometry; neutron reflectometry; thermal neutron detector;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
  • Conference_Location
    Anaheim, CA
  • ISSN
    1082-3654
  • Print_ISBN
    978-1-4673-2028-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2012.6551086
  • Filename
    6551086