Development of two dimensional thermal neutron flux monitor using multi-wire proportional counter for boron neutron capture therapy
Author
Tanaka, Hiroya ; Sakurai, Yasushi ; Suzuki, M. ; Masunaga, Shin-ichiro ; Hino, Masami ; Kinashi, Yuko ; Ono, Keishi ; Maruhashi, Akira
Author_Institution
Kyoto Univ. Res. Reactor Inst., Kumatori, Japan
fYear
2012
fDate
Oct. 27 2012-Nov. 3 2012
Firstpage
185
Lastpage
187
Abstract
At Kyoto University Research Reactor Institute, clinical studies of around 400 of Boron Neutron Capture Therapy (BNCT) have been performed using research reactor. On the other hand, we have developed cyclotron based epithermal neutron source. To improve the quality of treatment, it is necessary to perform the detection of two dimensional thermal neutron distribution before and during treatment as quality control. Generally, the method of activation using gold foiVwire and germanium semiconductor detector is applied to detection of thermal neutron flux at several positions. However, the activation method using semiconductor detector takes some time to decide the thermal neutron flux. Therefore, we propose the method using multi-wire proportional counter for detection of two dimensional thermal neutron distribution. We constructed the system consisting of multi-wire detection head, multi-channel preamplifier, multi-channel discriminator, centroid calculation circuit, and data acquisition system. Detection efficiency for BNCT irradiation field was evaluated using Am-Be neutron source with moderator for producing thermal neutrons. Furthermore, two dimensional thermal neutron distribution was demonstrably obtained.
Keywords
germanium radiation detectors; multiwire proportional chambers; neutron capture therapy; neutron sources; 2D thermal neutron distribution; 2D thermal neutron flux monitor; BNCT irradiation field; Kyoto University Research Reactor Institute; activation method; americium-beryllium neutron source; boron neutron capture therapy; centroid calculation circuit; cyclotron development; data acquisition system; epithermal neutron source; germanium semiconductor detector; multichannel discriminator; multichannel preamplifier; multiwire detection head; multiwire proportional counter; quality control; research reactor;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
Conference_Location
Anaheim, CA
ISSN
1082-3654
Print_ISBN
978-1-4673-2028-3
Type
conf
DOI
10.1109/NSSMIC.2012.6551089
Filename
6551089
Link To Document