Abstract :
At nuclear facilities, domestically and internationally, most measurement systems used for nuclear materials´ control and accountability rely on He-3 detectors. Due to resource shortages, alternatives to He-3 systems are needed. This paper presents preliminary simulation and experimental efforts to develop a fast-neutron-multiplicity counter based on liquid organic scintillators. This mission also provides the opportunity to broaden the capabilities of such safeguards measurement systems to improve current neutron-multiplicity techniques and expand the scope to encompass advanced nuclear fuels.
Keywords :
liquid scintillation detectors; nuclear materials safeguards; He-3 detectors; accountability; fast neutron multiplicity counter; liquid organic scintillator; nuclear materials safeguards; organic-scintillator neutron signature; passive measurement; resource shortage;
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
Conference_Location :
Anaheim, CA
Print_ISBN :
978-1-4673-2028-3
DOI :
10.1109/NSSMIC.2012.6551093