DocumentCode :
2546112
Title :
A sub-10ps resolution current discriminator for timing applications
Author :
Zhou, Xiaoxin ; Deng, Zhaohong ; Wang, Yannan ; Liu, Yanbing
Author_Institution :
Key Lab. of Particle & Radiat. Imaging, Beijing, China
fYear :
2012
fDate :
Oct. 27 2012-Nov. 3 2012
Firstpage :
581
Lastpage :
584
Abstract :
This paper uses a fully current-mode preamplifier and discriminator to get the accurate timing signal. The current discriminator has different mechanism from a voltage discriminator and hence its time resolution is dependent on both of the bandwidth and circuit gain. Detailed analysis will be present in the paper. The ASIC has been designed and tested with signals with different rise times and amplitudes. The result can verify the analysis that time jitter can be reduced by increasing the circuit gain. 10ps time resolution has been measured for signals with 2.5ns in rise time and only ~20μA above the threshold current.
Keywords :
application specific integrated circuits; discriminators; integrated circuit design; integrated circuit testing; nuclear electronics; preamplifiers; timing circuits; timing jitter; ASIC; bandwidth; circuit gain; current-mode preamplifier; sub10ps resolution current discriminator; time 10 ps; time jitter; time resolution; timing signal; voltage discriminator;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
Conference_Location :
Anaheim, CA
ISSN :
1082-3654
Print_ISBN :
978-1-4673-2028-3
Type :
conf
DOI :
10.1109/NSSMIC.2012.6551174
Filename :
6551174