DocumentCode :
2546604
Title :
Measurement of volatile impurities in iodine-based scintillator precursors
Author :
Swider, Stacy E. ; Motakef, Shariar ; Bliss, D.
Author_Institution :
CapeSym, Inc., MA, USA
fYear :
2012
fDate :
Oct. 27 2012-Nov. 3 2012
Firstpage :
708
Lastpage :
712
Abstract :
Alkaline-earth halides can be made into bright scintillators if purity is maintained during synthesis and growth. In order to investigate precursor purity, europium iodide, cesium iodide, and barium iodide beads were heated under vacuum and assessed by residual gas spectroscopy. Water and CO2 desorption, as well as iodide dissociation, was observed in Eul2 and BaI CsI sublimed and only released argon. The data inform approaches toward purification and growth.
Keywords :
barium compounds; caesium compounds; dissociation; europium compounds; scintillation counters; BaI; CsI; EuI; alkaline earth halides; barium iodide; cesium iodide; europium iodide; iodide dissociation; iodine based scintillator precursors; precursor purity; residual gas spectroscopy; volatile impurities measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
Conference_Location :
Anaheim, CA
ISSN :
1082-3654
Print_ISBN :
978-1-4673-2028-3
Type :
conf
DOI :
10.1109/NSSMIC.2012.6551197
Filename :
6551197
Link To Document :
بازگشت