DocumentCode :
2548610
Title :
Systematic study of RPC performances in polluted or varying gas mixture compositions: An online monitor system for the RPC gas mixture at LHC
Author :
Mandelli, B. ; Capeans, M. ; Guida, Raffaella ; Vitulo, P.
fYear :
2012
fDate :
Oct. 27 2012-Nov. 3 2012
Firstpage :
1135
Lastpage :
1140
Abstract :
A correct gas mixture composition is fundamental for proper and safe operation of the Resistive Plate Chamber large detector systems. At long term, small changes in the gas mixture composition can alter the RPC performance affecting the data quality in the ALICE, ATLAS and CMS experiments at CERN. A constant monitoring of the gas mixture quality injected in the RPC systems would possibly avoid this kind of problems. A systematic study has been performed to understand the RPC performances with slightly different gas mixture compositions and in presence of common impurities. The systematic analysis of several RPC parameters in different gas mixtures allows the quick identification of variations in the mixture. A set-up for the online monitoring of the RPC gas mixture in the LHC experiment is also proposed.
Keywords :
position sensitive particle detectors; ALICE experiment; ATLAS experiment; CERN; CMS experiment; LHC; RPC gas mixture compositions; RPC performances; online monitor system; resistive plate chamber; systematic analysis;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
Conference_Location :
Anaheim, CA
ISSN :
1082-3654
Print_ISBN :
978-1-4673-2028-3
Type :
conf
DOI :
10.1109/NSSMIC.2012.6551285
Filename :
6551285
Link To Document :