Title :
SPINTER: A new detector system for the INTER neutron reflectometer
Author :
Duxbury, D.M. ; Rhodes, N.J. ; Schooneveld, E.M. ; Spill, E.J. ; Webster, J.R.P.
Author_Institution :
Technol. Dept., Sci. & Technol. Facilities Council, Oxford, UK
fDate :
Oct. 27 2012-Nov. 3 2012
Abstract :
The development and testing of the SuPerior Rate for INTER (SPRINTER) detector is described. Based on a Microstrip Gas Chamber (MSGC) the aim of the project was to produce a matched pair of high counting rate detectors capable of replacing the existing 3He tubes currently used on the INTER reflectometer of the ISIS spallation neutron source. The detector system is described and the results from the first neutron beam tests carried out on an ISIS neutron reflectometer are also shown.
Keywords :
neutron sources; proportional counters; reflectometers; 3He tubes; INTER neutron reflectometer; ISIS spallation neutron source; SPRINTER detector; high counting rate detectors; microstrip gas chamber; neutron beam tests;
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
Conference_Location :
Anaheim, CA
Print_ISBN :
978-1-4673-2028-3
DOI :
10.1109/NSSMIC.2012.6551372