DocumentCode
2551650
Title
Application of isolation transformers for paper machine DC drives-a service perspective
Author
Jones, Roger W.
Author_Institution
Bowater Carolina Co., Catawba, SC, USA
fYear
1988
fDate
6-10 June 1988
Firstpage
145
Abstract
Summary form only given. Personal experience related to multiple paper-machine sectional drives grouped on one isolation transformer are presented. It is argued that, in such cases, from a service viewpoint, isolation transformers should be applied individually to every DC drive. This supplies the maximum isolation for the drive from interference caused by another drive. Based on experience, drives rated higher than 50 kW perform satisfactorily when grouped on isolation transformers. Armature-reversing DC drives with a maximum capacity rating of less than 50 kW perform much better with their own isolation. The author´s experience has shown that the problem is related more to the drive rating than the motor size. Individual isolation is required for small drives.<>
Keywords
electric drives; paper industry; power transformers; 50 kW; armature reversing DC drives; drive rating; isolation transformers; paper machine DC drives; Fuses; Guidelines; Interference; Maintenance engineering; Paper making machines; Phase transformers; Testing; Wounds;
fLanguage
English
Publisher
ieee
Conference_Titel
Pulp and Paper Industry Technical Conference, 1988., Conference Record of 1988 Annual
Conference_Location
Milwaukee, WI, USA
Type
conf
DOI
10.1109/PAPCON.1988.10918
Filename
10918
Link To Document