• DocumentCode
    2554291
  • Title

    Optical emission and probe diagnostics of inductively coupled Ar, O2, and Ar/O2 plasmas

  • Author

    Bae, M.K. ; Kang, H.R. ; Seo, M.W. ; Chung, T.H.

  • Author_Institution
    Department of Physics, Dong-A University, Busan, Korea
  • fYear
    2012
  • fDate
    8-13 July 2012
  • Abstract
    Properties of low-pressure inductively coupled argon, oxygen, and Ar/O2 mixture plasmas were investigated using optical emission spectroscopy (OES) and an rf-compensated Langmuir probe measurement. The electron energy probability function (EEPF), the electron density and electron temperature were obtained by using an rf-compensated Langmuir probe. The electron temperature was also obtained by OES models and compared with that measured by the probe. We evaluated the excitation temperature (Texc) and electron temperature (Te) in our plasmas by using the conventional and the modified Boltzmann plot method, respectively. We obtain two Boltzmann plots (conventional and modified) corresponding to plasmas with high argon content at low pressure, and show the change of Te as functions of pressure, argon content, and power. The values of Texc are found to be a little less than those of Te. However, both the plots give a reasonable estimation of Te and exhibit a similar trend of change with operating parameters. We have found that, in general, Te decreases with growing pressure and slightly decreases with argon content and power. The electron temperature is observed to decrease with power and with pressure and also observed to decrease with the Ar content. The EEPF in pure Ar plasmas shows a nearly Maxwellian. The EEPFs of oxygen discharges exhibit a rapid change with pressure due to many molecular collision processes. From pure Ar to Ar/O2 plasmas, the EEPF shows similar characteristics as in pure Ar plasmas, i.e. more depletion in the high-energy tail as the pressure increases. The Ar metastable density is also calculated based on the optical transition model. In Ar/O2 discharges, the dissociation fraction of molecules is estimated using optical emission actinometry. The dissociation fraction is observed to increase with the Ar content.
  • Keywords
    Argon; Optical variables measurement; Plasma temperature; Probes; Stimulated emission; Temperature measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Plasma Science (ICOPS), 2012 Abstracts IEEE International Conference on
  • Conference_Location
    Edinburgh
  • ISSN
    0730-9244
  • Print_ISBN
    978-1-4577-2127-4
  • Electronic_ISBN
    0730-9244
  • Type

    conf

  • DOI
    10.1109/PLASMA.2012.6383358
  • Filename
    6383358