    Evaluation of HYPR de-noising with MAP reconstruction in small animal PET imaging

  • Author

    Ju-Chieh Cheng ; Laforest, Richard

  • Author_Institution
    Sch. of Med., Dept. of Radiol., Washington Univ., St. Louis, MO, USA
  • fYear
    2012
  • fDate
    Oct. 27 2012-Nov. 3 2012
  • Firstpage
    2339
  • Lastpage
    2342
  • Abstract
    We describe an evaluation of the HighlY constrained back-PRojection (HYPR) de-noising in conjunction with the maximum a posteriori (MAP) reconstruction for the microPET-Inveon scanner. The HYPR technique involves the creation of a composite image from the entire duration of the dynamic scan. This image provides high signal-to-noise ratio (SNR) as well as high spatial resolution, and then it is updated by the weighting images generated from each individual dynamic frame to form the HYPR images. Consequently, as long as the composite image has a good SNR, the image quality of each dynamic frame with poor SNR can be improved. Dynamic mouse as well as static tumor imaging with high and low doses was performed to evaluate the advantages and limitations of the HYPR method. Time-activity-curve (TAC) comparison, precision vs accuracy in tumor/muscle ratio and mean absolute error vs number of counts were evaluated. It was found that HYPR can not only improve SNR and produce smoother TACs (on both single-voxel and region-of-interest levels) with lower variance but also be able to reduce the amount of dose injected. Two limitations were found: (1) at very low counts the low activity regions cannot be restored completely, and a positive bias in the estimated tumor/muscle ratio was obtained as a result, and (2) motion contamination between the composite and each dynamic image can introduce motion-artifact in the HYPR image. Therefore, motion needs to be corrected before applying HYPR.
  • Keywords
    image denoising; image motion analysis; image reconstruction; image resolution; maximum likelihood estimation; medical image processing; positron emission tomography; tumours; HYPR denoising; HYPR image; HYPR technique; HighlY constrained back-PRojection denoising; MAP reconstruction; composite image; count number; dynamic image; high signal-to-noise ratio; high spatial resolution; image quality; individual dynamic frame; low activity region; maximum a posteriori reconstruction; mean absolute error; microPET-Inveon scanner; motion contamination; motion-artifact; positive bias; region-of-interest level; single-voxel level; small animal PET imaging; static tumor imaging; time-activity-curve comparison; tumor/muscle ratio; weighting image;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
  • Conference_Location
    Anaheim, CA
  • ISSN
    1082-3654
  • Print_ISBN
    978-1-4673-2028-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2012.6551531
  • Filename
    6551531