• DocumentCode
    2554962
  • Title

    Electrocardiogram compression using lapped orthogonal transform

  • Author

    Ta, Nhi P. ; Attikiouzel, Yianni ; Crebbin, Greg

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Western Australia Univ., Nedlands, WA, Australia
  • fYear
    1990
  • fDate
    3-6 Jun 1990
  • Firstpage
    244
  • Lastpage
    251
  • Abstract
    The results of a study to examine the feasibility of electrocardiogram (ECG) data compression using the lapped orthogonal transform (LOT) are presented. The blocking effects in the reconstructed signal are shown to be reduced, while the bit rate and the performance of the proposed scheme remain the same, as compared with the traditional discrete cosine transform. A fast computing algorithm of the LOT adaptable for VLSI architectures is described
  • Keywords
    computerised signal processing; data compression; electrocardiography; medical diagnostic computing; transforms; VLSI architectures; bit rate; blocking effects; discrete cosine transform; fast computing algorithm; lapped orthogonal transform; reconstructed signal; Bit rate; Cardiology; Computer architecture; Data compression; Data engineering; Discrete cosine transforms; Discrete transforms; Electrocardiography; Karhunen-Loeve transforms; Very large scale integration;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computer-Based Medical Systems, 1990., Proceedings of Third Annual IEEE Symposium on
  • Conference_Location
    Chapel Hill, NC
  • Print_ISBN
    0-8186-9040-2
  • Type

    conf

  • DOI
    10.1109/CBMSYS.1990.109405
  • Filename
    109405